V-Sorb 2800S surface area analyzer introduction
V-Sorb 2800S is researched and
developed by Gold APP Instruments for single and multi-point BET surface area,
also with Langmuir surface area and others related with SSA by using static
volumetric principle. Compared with other companies’ analyzers, multi pioneered
techs make it’s performance much better, heighten accuracy and consistence of
results, enhance measurement stability, all these lead to a leading level in
international competitors. Products designed from the user perspective and
equipped with fully automated operation, user-friendly interface makes it easy
to learn, imported accessories assure stability and prolong life. Perfect
design, sophisticated production and strict testing guarantee to meet
customers’ real demands. High cost performance of V-Sorb 2800S easily ensure
your investment profits and flexible equipped peripheral can satisfy different
users’ requests.
V-Sorb 2800S surface area analyzer parameters
Analysis
Method: static volumetric nitrogen adsorption principle
Versatility: Adsorption and desorption isotherms,
Single and multi-point BET surface area, Average particle diameter estimation,
t-plot external surface area, True density analysis, Langmuir surface area,
carbon black (STSA), adsorption constant C.
Measuring
Ranges: 0.01m2/g to no known upper limit (surface area)
Accuracy: repeatability errors ≤1%
Vacuum
System: V-Sorb unique monolithic manifolds and solenoid valve control
system, greatly reduce the dead volume; improve the adsorbate micro-change
sensitivity; enhance pore size distribution analysis resolution; decrease
connecting points; strengthen sealing performance and prolonged instrument life
Coolant
Level Prober: V-Sorb original coolant level control system with temperature
probe, ensure the coolant level unchanged when compares with sample cells in
the whole analysis process, completely eliminate the analysis errors caused by
dead volume change
Sample
Treatment: the whole treatment procedures are controlled by dedicated
software, as well with a start time preset function which can realize
unattended operation at night
Control
System: programmable solenoid valve system with high integration and
strong anti-interference ability, enhance instrument’s stability and life
Sample
Ports: two samples’ analyzing and two samples’ degassing concurrently
Pressure
Measurement: imported sectional measuring dual pressure transducer, notably
improve the measuring accuracy at low P/Po point, 0-1000Torr
(0-133Kpa), 0-10Torr (0-1.33Kpa)
Transducer
Accuracy: imported silicon thin film pressure transducer, accuracy can
reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate
than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial
Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate
Vacuum: 4x10-2Pa (3x10-4 Torr)
Vacuum
Pump: built-in bipolar vacuum pump controlled by patented software
which can auto control pump’s start/stop
Adsorbate
Gas:
high purity nitrogen (≥99.999%), Ar, Kr, CO, C02, C4H10 etc. non-corrosive
gases are optional
Data
Acquisition: high-precision and high integration data acquisition modules,
minimal error, strong anti-interference ability
Data
Reduction: Windows®-based independent developed Gold APP softwareTM,
perfect versatility, produced full featured and multi-model reports
V-Sorb 2800S surface area analyzer features
A:
Vacuum System
1. Unique integral manifolds system,
decrease connecting points apparently, reduce leak rate, improve ultimate
vacuum.
2. Modularity design can configure as
customer requests, benefits future functions extension and instrument
maintenance.
3. Germany imported bipolar vacuum
pump, low noise, stable working, oil-return prevention; ultimate vacuum can
reach 4x10-2Pa (3x10-4Torr).
B:
Control System
1. Industry used programmable solenoid
valve system, strong anti-interference ability, convenient for installation and
uninstallation.
2. Separated analysis and treatment
manifolds can prevent foreign matter to contaminate manifolds in sample
treatment.
C.
Measures for Improving Accuracy
1. Imported silicon thin film
capacitive pressure transducer, accuracy can reach 0.1% of real reading, better
than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr
dual pressure transducers, sectional measurement in pressure range can reduce
errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate
than Pirani resistance vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds
system, decrease connecting points and reduce leak rate apparently.
4. Original stepping coolant level
control system, ensure the coolant level unchanged when compares with sample
cells in the whole analysis process, completely eliminate the analysis errors
caused by dead volume change.
5. Pioneered gas outlet and inlet
control system can efficiently prevent sample splash in evacuation and gas
inlet process, guarantee clean manifolds and sample weight unchanged, avoid
zero and liner drifting caused by transducer’s macro-change.
D.
Data Acquisition and Reduction
1. High precision and integration
data acquisition module is easy to connect, minimal errors and strong
anti-interference ability; standard 485 communication mode is good for
analyzer’s applications extension and interconnection, can also conveniently switched
to RS232 and USB modes.
2. Multi calculating methods for data
reduction provides all-round sample analysis options; powerful data archiving
and searching system helps a lot for data management.
V-Sorb 2800S surface area analyzer application
1. Super micro powder, nanomaterials,
particle and fiber shaped surface area analysis.
2. Product quality control for powder
materials related corporations.
3. Research institutes, universities
for BET theory teaching.
4. Fuel cells, catalysts, additives,
adsorbent, ceramics, magnetic materials, energy storage materials etc.
5. Other researches concern surface
area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments