F-Sorb 2400CE BET surface area analyzer introduction
F-Sorb
X400CE series surface area and porosity analyzers are new generation
instruments which were researched and developed by Gold APP Instruments Corporation
and China weapons institute. Innumerable independently patented techs make Gold
APP instruments enjoy great popularity at home and abroad. A high level of
precision and resolution, complicity of operation, speed, compact size, and
their stability guarantee our analyzers equally appropriate to industry quality
control, institutes, universities and laboratories. The weapons system’s high
demands and imported parts with original packaging had greatly improved
instruments’ reliability and life. The high cost performance of F-Sorb X400CE
series analyzers easily ensure your investment profits and flexible equipped
peripheral can satisfy different users’ demands.
F-Sorb
2400CE adopts speed and efficient continuous flowing gas (nitrogen) adsorption
principle, is an expert for contrast reference materials method, single and
multi-point BET method and Langmuir method analysis. BET method is universally
recognized and the most commonly used way for nitrogen adsorption surface area
analysis. No need of reference materials (RM) and utilizes sorption with
incorporates multilayer coverage to calculate surface area. Speedy testing,
high cost performances and easy operation make F-Sorb 2400CE be a desirable assistant
for quality control in production field, research institutes and universities.
F-Sorb 2400CE BET surface area analyzer parameters
Measuring Method: reference materials method, single
and multi point BET method, Langmuir surface area, adsorption and desorption
isotherm, average particle size estimate, carbon black external surface (STSA),
adsorption constant C analysis etc.
Measuring Ranges: 0.01 m2/g to no known upper limit (surface
area)
Accuracy: repeatability errors ≤1%
Analysis Control: 7 inch high sensitive color touch
screen with built-in PC operation system, providing USB linked keyboard and
mouse; external PC is supportable by RS232 communication port for a larger
operation interface; can be easily and quickly switched between two modes.
Safety Cover: transparent cover can protect
operators be hurt by liquid nitrogen splash; also can reduce liquid nitrogen
volatilization, extend its testing time and save your cost; more important is
the cover can isolate foreign environment influences to the analysis
procedures, naturally, improve data stability and accuracy.
Flow Rate Adjust: Gold APP Instruments patented F-Sorb
micro stepping motor can realize flow rate auto-adjust for every P/Po point
in BET analysis; flow rate value auto-collected by software and real-time displayed
in interface
Quantitative Dosing: patented F-Sorb quantitative pipe
TM desorbs automatically, realized auto dosing for sample desorption
isotherm, manual pipeline switch is not required
Manifolds Sealing: high vacuum system with stainless steel
manifolds, sound sealing performance can eliminate errors caused by gas
molecules permeation
Sample Types: powders, particle, fiber, flakes
and other species
Sample Ports: 4 samples simultaneously
Analysis Gases: high purity (99.99%) Helium as
carrier; Nitrogen (99.99%) as adsorbate; Ar, Kr etc. are
optional
Time: less than 5 minutes for every P/Po
point’s adsorption and desorption; analysis data will present automated by Gold
APP softwareTM
Pressure Required: atmospheric pressure, no need
vacuum, save experiment time
Data Acquisition: high precision and integration
chip, minimal errors, strong anti-interference ability
Data Reduction: Windows®-base independently
developed Gold APP softwareTM, perfect versatility, ease of use and
multi-model data reduction reports
Operation System: multifunctional, fully automated,
highly intelligent operation system
F-Sorb 2400CE BET surface area analyzer features:
Fully automated, farewell to complex manual operation; minimal user
intervention;
promote efficiency.
A. Structure Design
1.
Stainless manifolds system is much better than plastic manifolds, obviously
enhances sealing performance, eliminates errors caused by gas molecules
permeation, no ageing for manifolds, increase reliability and prolong life,
more appropriate for humid environment.
B. Control System
1.
Integrated multifunctional control system; motor screw rod lifting system
ensures Dewar stability.
2.
Innovated balanced bridge circuit greatly improves signal voltage sensitivity,
as well as achieves auto balance of signal zero drift.
3.
Fully-auto operation, minimal operator involvement and work efficiency
improved.
C. Data Acquisition and Reduction
1.
High precision data acquisition and signal amplification, high integrated A/D
transformation system, strong anti-interference ability and high real time, can
reduce environmental influence on analysis procedures.
2.
Utilize super sensitive thermal conductivity detection and balance system can
increase detectable signal range; zero drift auto calibration system enhances
stability and accuracy.
3.
Independently innovated Windows® compatible software, versatile
applications, flexible customer-tailor interface, ease of use; self developed
data reduction module can efficiently eliminate system errors and improve
precision.
4.
Customer made data reports and diversified data calculation models are
convenient for data analyzing; powerful data archiving and searching capacity
helps a lot for data management.
D. Analysis Optimize
1.
Multi analysis methods, no need to convert operations frequently, all set in dedicated
software.
2.
Contrast reference materials method and BET method can switch freely, simplify operation
steps and improve measurement efficiency.
3.
Pioneered gas amount auto-adjust system brings extremely accurate, stable and
no user intervention analysis.
4.
Can be upgraded to F-Sorb 3400CE.
F-Sorb 2400CE BET surface area analyzer applications
1.
Super micro powder, nanomaterials, particle and fiber shaped surface area
analysis.
2.
Product quality control for powder species related corporations.
3.
Research institutes, universities for BET theory teaching.
4.
Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials,
energy storage materials etc.
5.
Other researches concern surface area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments