V-Sorb
4800S surface area analyzer introduction
V-Sorb 4800S is developed by Gold APP
Instruments for surface area determination which utilizes static
volumetric method. Compared with other companies’ analyzers, multi pioneered
technologies make instrument’s performance much better, heighten accuracy and
consistence of results, enhance measurement stability, all these lead to a
leading level in world market. Analyzers designed from the user
perspective and equipped with fully automated operation and user-friendly
interface make it easy to learn, imported accessories assure stability and
prolong life. Perfect design, sophisticated production and strict testing
guarantee to meet customers’ real demands. High cost performance of V-Sorb
4800S easily ensure your investment profits and flexible equipped peripheral
can satisfy different users’ requests.
V-Sorb
4800S surface area analyzer parameters
Analysis Method: static volumetric nitrogen adsorption
principle
Versatility: Adsorption and desorption
isotherms, Single and multi-point BET method, Langmuir surface area,
t-plot external surface area analysis, True density analysis, carbon
black STSA etc.
Measuring Ranges: 0.01m2/g to no known upper
limit (surface area)
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds
and solenoid valve control system, greatly reduce the dead volume; improve the
adsorbate micro-change sensitivity; enhance pore size distribution analysis
resolution; decrease connecting points; strengthen sealing performance and
prolonged instrument life
Coolant Level Controller: V-Sorb original coolant level
control system with temperature probe, ensure the coolant level unchanged when
compares with sample cells in the whole analysis process, completely eliminate
the analysis errors caused by dead volume change
Control System: programmable solenoid valve system
with high integration and strong anti-interference ability, enhance
instrument’s stability
Sample Ports: four samples’ analyzing and four
degassing concurrently
Pressure Measurement: imported sectional measuring dual
pressure transducer, notably improve the measuring accuracy at low P/Po
point, two transducers’ 0-1000Torr (0-133Kpa)
Transducer Accuracy: imported silicon thin film pressure
transducer, accuracy can reach 0.1% of real reading, better than 0.1% of
F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general
error is 10%-15%)
Partial Pressure: P/Po controllable
accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
Vacuum Pump: built-in bipolar vacuum pump
controlled by patented software which can auto control pump’s start/stop
Adsorbate Gas: high purity nitrogen(≥99.999%), Ar,
Kr, CO2 etc. non-corrosive gases are optional
Data Acquisition: high-precision and high integration
data acquisition modules, minimal error, strong anti-interference ability
Data Reduction: Windows®-based independent
developed Gold APP softwareTM, perfect versatility, produced full
featured and multi-model reports(txt, word, excel, pdf)
Specifications: Height 22.05 inches (56cm)* Width 20.87
inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)
V-Sorb
4800S surface area analyzer features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting points
apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests,
benefits future functions extension and instrument maintenance.
3. Germany
imported bipolar vacuum pump, low noise, stable working, oil-return prevention;
ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry used programmable solenoid valve system, strong
anti-interference ability, convenient for installation and uninstallation.
2. Separated analysis and treatment manifolds can prevent
foreign matter to contaminate manifolds in sample treatment.
C. Measures for Improving Accuracy
1. Imported silicon thin film capacitive pressure transducer,
accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers,
sectional measurement in pressure range can reduce errors in low vacuum,
0-10Torr silicon thin film transducer is highly accurate than Pirani resistance
vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting
points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure the
coolant level unchanged when compares with sample cells in the whole analysis
process, completely eliminate the analysis errors caused by dead volume change.
5. Pioneered gas outlet and inlet control system can efficiently
prevent sample splash in evacuation and gas inlet process, guarantee clean
manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s
macro-change.
D. Data Acquisition and Reduction
1. High precision and integration data acquisition module is
easy to connect, minimal errors and strong anti-interference ability; standard
485 communication mode is good for analyzer’s applications extension and
interconnection, can also conveniently switched to RS232 and USB modes.
2. Multi calculating methods for data reduction provides
all-round sample analysis options; powerful data archiving and searching system
helps a lot for data management.
V-Sorb
4800S surface area analyzer application
1. Super micro powder, nanomaterials, particle and fiber shaped
surface area analysis.
2. Product quality control for powder materials related
corporations.
3. Research institutes, universities for BET theory teaching.
4. Full cells, catalysts, additives, adsorbent, ceramics,
magnetic materials, energy storage materials etc.
5. Other researches concern surface area performance.
Contact info:
Email:
sales@jinaipu.com
Tel.: 0086-10-82133318 Ext.810
Fax: 0086-10-82118197
Mobile: 0086-18210009838
IMs:
Skype: Gold-APP-Instruments