Thursday, January 7, 2016

Specific Surface Area and Porosity Analyzer Exported to Canada Manson Environmental Corporation


Gold APP Instruments Corporation China had export one set volumetric specific surface area and porosity analyzer to Canada catalyst manufacturer--Manson Environmental Corporation. This is the first set Chinese brand analyzer came into Canada market.

 

Manson Environmental Corporation is an inorganic chemicals manufacturer in Oakville. This private company was founded in 1986.

 
Gold APP Instruments China also produce gas pycnometer analyzer for true density, the open and closed pore cells testing; high pressure volumetric adsorption analyzer for PCI, TPD, adsorption/ desorption isotherms testing. Welcome email to sales@jinaipu.com for more details.

Wednesday, November 18, 2015

Cooperated with Singapore Polytechnic for BET Surface Area and Porosimetry Analyzer





Gold APP Instruments China had
signed one set BET surface area and porosimetry analyzer by volumetric
adsorption principle with Singapore
Polytechnic
under the help of LEE HUNG
SCIENTIFIC PTE LTD
. Recently, Gold APP Instruments China finished the
installation and calibration work for Singapore Polytechnic.




 




Singapore Polytechnic is the
first polytechnic established in Singapore. It was founded on 27 October 1954
to provide studies, training and research in technology, science, commerce and
the arts. 2010 saw Singapore Polytechnic's 50th graduation ceremony and
150,000th graduate. To date, over 177,000 students have graduated from
Singapore Polytechnic.




 




Gold
APP Instruments China also produce gas pycnometer analyzer for true density,
the open and closed pore cells testing; high pressure volumetric adsorption
analyzer for PCI, TPD, adsorption/ desorption isotherms testing. Welcome email
to
sales@jinaipu.com for more details.






BET Surface Area|Porosity Analyzer|Gas Pycnometer Helium True Density Equipment|High Pressure Volumetric Analyzer| Langmuir/BET/Gibbs/BJH/MP/SF/DR/DA/HK/T-Plot Analyzer

Sunday, July 5, 2015

BET Surface Area Analyzer| Pore Size Analyzer | Gas Pycnometer True Density Analyzer | High Pressure Volumetric Analyzer | Langmuir/Isotherm/BJH/SF/DR/DA/MP/HK/t-Plot/PCT(Pressure-Composition-Temperature) Analyzer--Gold APP Instruments

BET Surface Area Analyzer| Pore Size Analyzer | Gas Pycnometer True Density Analyzer | High Pressure Volumetric Analyzer | Langmuir/Isotherm/BJH/SF/DR/DA/MP/HK/t-Plot/PCT(Pressure-Composition-Temperature) Analyzer--Gold APP Instruments








 




Agents Are Wanted
for Gas Sorption Analytical Instruments




 




Gold APP Instruments Corporation China is a
professional manufacturer for gas sorption analytical instruments researching,
producing, selling and servicing.




 




Our analyzers cover BET surface
area analyzers
, surface area
and porosity analyzers
, gas
pycnometer true density analysers
, high pressure
gas sorption volumetric analysers
, sample
degassers
and so on for nanomaterials, nanoparticles etc materials
measurement. Can be used for universities, research institutes, factories QC
etc.




 




Analyzer Classified as:




1.      
BET surface area
analyzers




















2.      
surface area and
porosity analyzers




























3.      
gas pycnometer
helium true density analyser








4.      
high pressure gas
sorption volumetric analyzer








 




Contact us to talk more details.








Email:
sales@jinaipu.com




Tel.:
0086-10-82132122




Fax:
0086-10-82118197




Mobile:
0086-18210009838




Skype:
Gold-APP-Instruments




Yahoo:
goldappinstruments@ymail.com


Wednesday, May 13, 2015

Gold APP Instruments Had Signed a Set Surface Area and Porosity Analyzer with Ariel University of Samaria


Gold APP Instruments Corporation China had signed a set surface area and porosity analyzer with Ariel University of Samaria, Israel. This is a landmark for Chinese manufacturers because we are the first one go into Israel market till now.

 

The Ariel University of Samaria informed us that they had already bought one surface area and porosity analyzer from American manufacturer, but that model had already out of date and not highly automated, also cost a huge money for daily maintenance. Thus, the Ariel University of Samaria had decided to buy one new set surface area and porosity analyzer which should be highly auto operation, can work for 24 hours without stop and has a competitive price than USA old model. After many times trail test service for client’s samples, they decided to purchase our static volumetric principle surface area and porosity analyzer because our data (see below) are better than their old analyzer data.

 

Ariel University (Hebrew: אוניברסיטת אריאל‎), previously known as the Ariel University Center of Samaria, is an Israeli university located in the Israeli settlement of Ariel in the West Bank. Ariel University was founded in 1982 as a regional branch of Bar-Ilan University. In 2011, it had a student population of 14,000, with a branch in Tel Aviv. All degrees are recognized by the Council for Higher Education in Israel.
 

Gold APP Instruments Had Finished the Surface Area and Porosimetry Analyzer Calibration for National Center for Scientific Research Demokritos, Greece


Gold APP Instruments Corporation China had signed one surface area and porosimetry analyzer procurement agreement with National Center for Scientific Research Demokritos, Greece at March, 2015. At recent, we finished the calibration work for NCSR Demokritos and won their positive feedbacks and praise.

 

The National Center for Scientific Research “Demokritos” (NCSR “Demokritos”) is the largest multidisciplinary research center in Greece, with critical mass in expertise and infrastructure in the fields of Nanotechnology, Energy & Environment, Biosciences, Particle and Nuclear Science, Informatics and Telecommunications. The Center was inaugurated in 1961 as a state-owned entity under the name Nuclear Research Center “Demokritos”, following the coming into operation of the nuclear reactor research facility. The NCSR “Demokritos” conducts world-class basic and applied research, for advancing scientific knowledge and promoting technological development in selected areas of national socio-economic interest. The Center also plays a pivotal role in graduate education and professional training and its unique infrastructure is employed for high-technology services to the Industry and the Society.

 

The NCSR “Demokritos” wants this surface area and porosimetry analyzer to determine BET surface area, BJH pore size, pore volume etc data for their newly researched catalysts. Our surface area and porosimetry analyzer V-Sorb 2800 employ the static volumetric nitrogen adsorption principle, has 2 analysis ports and 2 degassing ports, fully automated operation controlled by dedicated software, with a preset function helps 24 hours testing, a 4 liter stainless Dewar can meet microporous and mesoporous materials determination. Please find us (sales@jinapu.com) if you want to know more.

Wednesday, November 13, 2013


V-Sorb 4800S surface area analyzer introduction

 

V-Sorb 4800S is developed by Gold APP Instruments for surface area determination which utilizes static volumetric method. Compared with other companies’ analyzers, multi pioneered technologies make instrument’s performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in world market. Analyzers designed from the user perspective and equipped with fully automated operation and user-friendly interface make it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. High cost performance of V-Sorb 4800S easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.

 

 

V-Sorb 4800S surface area analyzer parameters

 

Analysis Method: static volumetric nitrogen adsorption principle

Versatility: Adsorption and desorption isotherms, Single and multi-point BET method,  Langmuir surface area, t-plot external surface area analysis, True density analysis,  carbon black STSA etc.

Measuring Ranges: 0.01m2/g to no known upper limit (surface area)

Accuracy: repeatability errors ≤1%

Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Controller: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability

Sample Ports: four samples’ analyzing and four degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, two transducers’ 0-1000Torr (0-133Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998

Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)

Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop 

Sample Types: powders, particle, fiber, flakes and other materials

Adsorbate Gas: high purity nitrogen(≥99.999%), Ar, Kr, CO2 etc. non-corrosive gases are optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-based independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports(txt, word, excel, pdf)

Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)

 

 

V-Sorb 4800S surface area analyzer features

 

A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

 

B: Control System

1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

 

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.

 

D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.

 

 

V-Sorb 4800S surface area analyzer application

 

1. Super micro powder, nanomaterials, particle and fiber shaped surface area analysis.

2. Product quality control for powder materials related corporations.

3. Research institutes, universities for BET theory teaching.

4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.

 

 

Contact info:



Email: sales@jinaipu.com

Tel.: 0086-10-82133318 Ext.810

Fax: 0086-10-82118197

Mobile: 0086-18210009838

IMs:

Skype: Gold-APP-Instruments



 

BET surface area analyser V-Sorb 2800S


V-Sorb 2800S surface area analyzer introduction

 

V-Sorb 2800S is researched and developed by Gold APP Instruments for single and multi-point BET surface area, also with Langmuir surface area and others related with SSA by using static volumetric principle. Compared with other companies’ analyzers, multi pioneered techs make it’s performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in international competitors. Products designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers’ real demands. High cost performance of V-Sorb 2800S easily ensure your investment profits and flexible equipped peripheral can satisfy different users’ requests.

 

 

V-Sorb 2800S surface area analyzer parameters

 

Analysis Method: static volumetric nitrogen adsorption principle

Versatility: Adsorption and desorption isotherms, Single and multi-point BET surface area, Average particle diameter estimation, t-plot external surface area, True density analysis, Langmuir surface area, carbon black (STSA), adsorption constant C.

Measuring Ranges: 0.01m2/g to no known upper limit (surface area)

Accuracy: repeatability errors ≤1%

Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night

Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument’s stability and life

Sample Ports: two samples’ analyzing and two samples’ degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998

Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)

Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop 

Sample Types: powders, particle, fiber, flakes and other materials

Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, C02, C4H10 etc. non-corrosive gases are optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-based independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports

 

 

V-Sorb 2800S surface area analyzer features

 

A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

 

B: Control System

1. Industry used programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

 

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.

 

D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.

 

 


V-Sorb 2800S surface area analyzer application

 

1. Super micro powder, nanomaterials, particle and fiber shaped surface area analysis.

2. Product quality control for powder materials related corporations.

3. Research institutes, universities for BET theory teaching.

4. Fuel cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.

 

Contact info:



Email: sales@jinaipu.com

Tel.: 0086-10-82133318 Ext.810

Fax: 0086-10-82118197

Mobile: 0086-18210009838

IMs:

Skype: Gold-APP-Instruments